Air Source Heat Pump Water Heater Commercial Use
KONNEN BRAND OF AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE: WE SUPPLY OEM SERVICE! KONNEN NEW FACTORY(
Send your inquiryDESCRIPTION
Basic Info
Model NO. | A02H 12-165KW |
Energy Efficiency Grade | One |
Heat Temperature | 50-70°C |
Work Environment | Common Heat Pump |
Heat Source | Air-source |
Heating Type | Circulating Heat |
Application | Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons |
Certification | CE, ISO9001, CCC |
Product Name | Air Source Commercial Use Heat Pump (Kfxrs) |
Compressor | Panasonic or Copeland |
Refrigerant | R410A |
Heating Capacity | 12~105kw |
Rated Produce Hot Water Capacity | 258-2257L/H |
Transport Package | Safety Export Packing |
Specification | standard |
Trademark | CEN (Creative Power) |
Origin | Zhejiang, China( Main Land) |
HS Code | 8418612090 |
Production Capacity | 5000 PCS Per Month |
Product Description
KONNEN BRAND OF AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE:* Panasonic compressor & R410a refrigerant, OR Copeland compressor and R410a refrigerant; |
* Stainless steel 304 for all fasteners, for side covers of evaporator; |
* Preservative oil for copper tubes and all important part of cabinet; |
* Chinese No.1 brand "ND" shell & tube heat exchanger; |
* Japan "Saginomiya" or "Sanhua" electronic expansion valve; |
* "Sanhua" 4-way valve; |
* "Schneider" AC contactor & Relay |
* LCD controller; |
* Delivery time: 20~25 days; |
* Payment term: T/T 30% in advance and T/T 70% before delivery; |
* Warranty time: 24 months after delivery. |
WE SUPPLY OEM SERVICE!
KONNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
WHY US:
KONNEN NEW PROJECTS:
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
KONNEN HEAT PUMPS LOADING:
PARAMETERS TABLE:
A02H series (Air source heat pump water heater circulation type) | ||||||||||||||
HW03Ps-E3 | HW05Ps-E5 | HW03P-E3 | HW05P-E5 | HW07P-E5 | HW10P-C24 | HW14P-C24 | HW20P-C48 | HW24P-C48 | HW30P-C48 | HW36P-C48 | HW48P-C96 | |||
Rated heating capacity | kW | 12 | 19 | 12 | 19 | 25 | 35 | 50 | 75 | 85 | 105 | 125 | 165 | |
Rated input power | kW | 2.75 | 4.39 | 2.75 | 4.37 | 5.75 | 8.10 | 11.57 | 17.20 | 19.60 | 24.20 | 28.90 | 38.10 | |
Rated input current | A | 14.05 | 23.10 | 5.17 | 8.34 | 10.77 | 15.00 | 23.86 | 31.80 | 37.00 | 46.10 | 53.50 | 72.30 | |
Maximum input power | kW | 3.38 | 5.40 | 3.38 | 5.38 | 7.07 | 9.96 | 14.23 | 21.16 | 24.11 | 29.77 | 35.55 | 46.86 | |
Maximum input current | A | 18.28 | 29.19 | 6.43 | 10.21 | 13.44 | 18.93 | 27.05 | 40.20 | 45.81 | 56.56 | 67.54 | 89.04 | |
Performance coefficient(COP) | / | 4.36 | 4.33 | 4.36 | 4.35 | 4.35 | 4.33 | 4.32 | 4.36 | 4.34 | 4.34 | 4.33 | 4.33 | |
Rated hot water output temp. | ºC | 55 | ||||||||||||
Max. hot water output temp. | ºC | 60 | ||||||||||||
Rated hot water produce capacity | L/H | 258 | 408 | 258 | 408 | 537 | 752.5 | 1075 | 1612.5 | 1827.5 | 2257.5 | 2687.5 | 3547.5 | |
Power supply | 1N 220V/50Hz | 3N 380V/50Hz | ||||||||||||
Compressor | Type | Fully closed scroll type | ||||||||||||
Start Mode | Directly start | |||||||||||||
Quantity | Set | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 4 | 2 | 3 | 3 | 4 | |
Water side heat exchanger | Type | Shell & coil(tube) heat exchanger | ||||||||||||
Water flow | m3/h | 2.1 | 3.3 | 2.1 | 3.3 | 4.3 | 6.0 | 8.6 | 12.9 | 14.6 | 18.1 | 21.5 | 28.4 | |
Water Pressure Drop | kPa | ≤50 | ≤55 | ≤50 | ≤55 | ≤55 | <60 | <60 | <65 | <65 | <65 | <65 | <65 | |
Pipe size | DN | DN20 | DN25 | DN20 | DN25 | DN25 | DN32 | DN32 | DN50 | DN50 | DN50 | DN65 | DN80 | |
Protections | 1. High pressure and low pressure protection, 2. Anti-freezing protection, 3. High temperature protection, 4. Too big of the water temperature difference for outlet and inlet protection, 5. Overload protection, 6. Lack phase protection, 7. Reverse phase protection, etc.. | |||||||||||||
Refrigerant | Throttle Type | Electronic expansion valve | ||||||||||||
Quantity | kg | 1.9 | 2.8 | 1.9 | 2.8 | 4.1 | 2.8×2 | 4.1×2 | 3.2×4 | 7.6×2 | 6.2×3 | 7.6×3 | 7.6×4 | |
Noise | DB(A) | ≤55 | ≤63 | ≤55 | ≤63 | ≤65 | ≤65 | ≤68 | ≤70 | ≤72 | ≤73 | ≤74 | ≤78 | |
Dimension | mm | 700×680× 875 | 820×695× 1060 | 700×680× 875 | 820×695× 1060 | 820×695× 1060 | 1000×1000×1858 | 1000×1000×1858 | 1000×2050×1900 | 1000×2050×1900 | 1000×2050×1980 | 1000×2050×1980 | 2000×2050×1980 | |
Net Weight | kg | 100 | 160 | 100 | 160 | 190 | 310 | 400 | 605 | 650 | 835 | 840 | 1230 | |
Testing conditions: | ||||||||||||||
1. Application side initial water temperature: 15ºC, end temperature 55ºC, max. temperature 60ºC. | ||||||||||||||
2. Ambient temperature dry bulb 20ºC, wet bulb 15ºC. | ||||||||||||||
The above parameters are based on Refrigearnt R410a, for parameters based on other refrigerant please contact us. | ||||||||||||||
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret. |
Related Products